GE Corometrics 170 Series Fetal Monitors

Whether you perform antepartum fetal monitoring in an office environment or in the hospital, the Corometrics * 170 Series Fetal Monitor can help. You can rely on our fetal monitors to help you improve the standard of care for your expectant mothers. We designed these compact and lightweight monitors to help you effectively and efficiently care for mom and baby through accurate and non-invasive tracking of the baby’s heart rate for stress-free testing. The 170 series is used with our Toco ultrasound transducers and Nautilus * 9-glass, watertight and lightweight, for convenient and reliable monitoring.

  • Alert on fetal heart rate problems – The fetal heart rate alarm provides audible and visual alerts if the heart rate is higher or lower than the range you established as normal
  • Helps you position the transducer – Independent volume controls make it easier to locate the transducer for more effective monitoring
  • Can control multiple heart rates – There is an option to monitor twins
  • Sign important information prominently – Large, easy-to-read LCD display clearly presents information on fetal heart rate and uterine activity
  • Portability of the offers – An optional mobile trolley allows you to transport the monitor and all its necessary accessories
Formulario de Contacto Productos
Primer y segundo nombre
Apellidos completos
PARA MAS INFORMACIÓN CONTÁCTENOS AL:

Clic Aquí-Enviar mensaje a WhatsApp

+57 304 355 13 63

+57 4 322 36 03

+1 707 294 8221

Description

Dimensions

  • Height x Width x Depth: 14.6 x 42.5 x 25.4 cm (5.75 x 16.75 x 10 inches)
  • Weight: approximately 3.6 kg (8 pounds)

energy requirements

  • Nominal line voltage: 100-230 VAC
  • Line frequency: 50/60 Hz (operates on 47-63 Hz)
  • Power consumption: ≤ 30 VA
  • Monitor DC input: 12 Vdc to 2.5A

Performance specifications

  • Pulsed Doppler technique with automatic correlation processing
  • Type of transducer 9-crystal
  • Repeat pulse 2 kHz (all modes)
  • Frequency Pulse duration 92 μs
  • Transmitter frequency 1,151 MHz
  • Spatial-Temporal Isata <5 mW / cm2
  • Medium intensity
  • Focal 20 dB Beam Area 16.6 cm2, in a range = 7 cm
  • Instant peak 1.8 mW / cm2
  • Intensity
  • Heart rate Counting range 50-210 BPM
  • Leakage current Meets the harmonized national standard IEC 60 1.1 and / or IEC 601.1.1; Complies with EN 60601-1-2: 2002

FECG mode

  • Technique: Peak detection, beat-to-beat cardiotechometer
  • Heart rate range: 30-240 BPM
  • Heart rate resolution: 1 BPM
  • Artifact removal: selectable service, artifact rejection of ± 25 BPM
  • Counter input signal range: 15μV to 2mV peak to peak
  • Compensation voltage tolerance (differential): ± 300 mVdc maximum
  • Maximum common mode voltage: 20V peak to peak
  • Rechazo de modo común: Equilibrado:> 120 dB a la frecuencia de red, con cable del paciente, 5kΩRA o LA:> 110 dB a la frecuencia de red
  • Impedancia de entrada: Diferencial:> 10MΩ; Modo común:> 20MΩ
  • Rechazo de frecuencia de red:> 40 dB
  • Corriente de fuga: cumple con la norma nacional armonizada IEC 601.1 y / o IEC 601.1.1
  • Aislamiento, de la red al paciente:> 5656 Vdc

Modo de ultrasonido

  • Técnica: Doppler pulsado con proceso de autocorrelación
  • Tipo de transductor de transferencia: 9-crystal
  • Frecuencia de repetición de pulso: 2 kHz (todos los modos)
  • Duración del impulso: 92 μs
  • Frecuencia del transmisor: 1.151 MHz
  • Espacio-Promedio de la intensidad media temporal: Isata <5 mW / cm²
  • Focal 20 dB área del haz: 16.6 cm², en un rango = 7 cm
  • Intensidad instantánea máxima: 1,8 mW / cm²
  • Frecuencia cardiaca: 50-210 BPM
  • Corriente de fuga: cumple con la norma nacional armonizada IEC 601.1 y / o IEC 601.1.1