Philips HP 50XM M1360b Fetal Monitor

The Fetal / Maternal monitor of the 50 XM Philips series is designed for health professionals properly trained for use in the patient’s environment to monitor the fetal and maternal condition before and during labor and delivery.

  • Fully integrated fetal and maternal monitoring system
  • For use with high-risk patients or patients receiving anesthesia during labor and delivery
  • Power requirements: Operating voltage 100 – 120 V (± 10%), 220 – 240 V (± 10%), Line frequency 50 to 60 Hz, Power consumption 60 VA max.
  • Dimensions and weight without transducers
    • Height 147 mm (5.8 inches)
    • Width 422mm (16.6in)
    • Depth 392mm (15.4in)
    • Weight 14.6kg (31.96lb)
Formulario de Contacto Productos
Primer y segundo nombre
Apellidos completos
PARA MAS INFORMACIÓN CONTÁCTENOS AL:

Clic Aquí-Enviar mensaje a WhatsApp

+57 304 355 13 63

+57 4 322 36 03

+1 707 294 8221

Description

Philips HP 50XM Specifications

Fetal Dispay

  • Maternal non-invasive blood pressure
  • Heart rate range US 50 to 240 bpm, DECG 30 to 240 bpm, MHR 30 to 240 bpm (not shown)
  • Outer Toco Range 0 to +127 relative units
  • Range IUP -99 to +127 mmHg
  • Fetus SpO2 Range 0 – 99%
  • Accuracy of the pressure transducer 15 ° C at 25 ° C ± 3 mmHg, 10 ° C at 35 ° C ± 3 mmHg (± 0.6% of reading), 0 ° C to 55 ° C ± 3 mmHg (± 1 , 7% of reading)
  • Measuring ranges Systolic 30 to 270 mmHg Diastolic 10 to 245 mmHg
  • Cuff inflation rate Typically less than 10 seconds
  • Repetition time of automatic mode 2, 5, 10, 15, 30, 60 minutes
  • Statistic mode Duration 5 minutes Non-invasive maternal blood pressure
  • Cycle time (Typical in HR over 60 bpm) Auto / manual 35 seconds, Stat 17 seconds, Maximum 120 seconds
  • Adjustment of limited alarms 5 mmHg steps, diastolic 10 to 245 mmHg, systolic 30 to 270 mmHg, safety limit of overpressure 300 mmHg for more than 2 seconds
  • Pulse rate range Measurable within the heart rate range of 30 to 240 bpm, averaged during the NIBP measurement
  • Pulse Oximetry Maternal ECG and Heart Rate Range from 0 to 100%
  • BPM range 30 to 300 bpm
  • Accuracy ± 1%
  • Resolution 1 bpm
  • Pulse Rate Limit Alarm Range 70% – 90%, Adjust 1% steps
  • Accuracy to 1 standard deviation M1191A 70 to 100% ± 2.5%, M1192A 70 to 100% ± 2.5%, M1194A 70 to 100% ± 4%, Nellcor sensors 80 to 100% ± 3%
  • Heart rate Measuring range 30 to 240 bpm, Accuracy ± 1 bpm, Resolution Recorder: 0.25 bpm, Display: 1 bpm
  • Heart rate alarm limits (excluding NIBP) Range 30 to 250 bpm, Adjust 5 steps of BPM
  • Numerical display of the maternal screen Two displays of heart rate (orange) and a visualization of uterine activity (green). Type: (10mm) 7 segment LEDs

Maternal Dispay

  • Systolic measurement
  • Diastolic measurement
  • SpO2 level
  • Maternal heart rate (if derived from MECG), pulse rate (if derived from pulse oximetry) or average pulse rate (if derived from NIBP)
  • Alarm status for each parameter (except the NIBP pulse frequency)
  • Warning message (if any)

 

Reviews

There are no reviews yet.

Be the first to review “Philips HP 50XM M1360b Fetal Monitor”

Your email address will not be published. Required fields are marked *